Tutorials
How to Replace a CAD Model
In some cases, an existing CAD model may need to be replaced due to a revision change or other design updates. Rather than creating a new program from scratch, it is generally more efficient to replace the existing CAD model and re-teach only the ...
Programming with Part and Fixture CAD Models
The main advantage of utilizing the fixture CAD file in conjunction with the part model is that CMM-Manager will generate a measurement path to avoid both details, eliminating any manual adjustments. For example, programming the part shown in the ...
Picking Features for Alignment, Constructions, and Reporting
There are several methods available for selecting individual or multiple items within CMM-Manger: 0:00 Mouse Picking (from CAD) 0:21 Drag-n-Drop (from Feature Database) 0:52 Right Click (Drop down menu)
Programming with Renishaw Equator
Although the standard CMM-Manager knowledge applies, there are subtle differences that must be aware of when programming for Equator. Requirements: CMM-Manager 2023 or newer with Renishaw Equator driver Standard Renishaw I++ driver will NOT be ...
Creating a Program Offline
Overview: The offline programming capability will enable the user to create inspection programs outside of CMM-Manager installed on a CMM workstation. This reduces the CMM downtime significantly caused by the online programming process, which could ...
Shop Floor Launcher (SFL)
CMM-Manager's Shop Floor Launcher (SFL) allows a programmer to custom create a simple, browser-like interface for an operator to use on the shop floor. The interface is touch-screen friendly and will allow the operator to quickly and easily access an ...
Setting the Machine Volume and Table Height
When using a Renshaw UCC controller with UCC Server 5.0 and above in I++ mode, sync of these values should be automatic. If the settings are still not correct, beginning in CMM-Manager 2022, the preferred method is to use the instructions here. If ...
How To - Setting up a CMM-Manager Network License
To set up a network license, please follow the instructions listed below. Setting up the License Host PC Host PC as a license server and CMM-Manager Note: Using CMM-Manager on this PC will use one of the available licenses Install CMM-Manager Host PC ...
LeapFrog - inspect parts larger than CMM volume
The Leap Frog tool allows moving the part or (portable) CMM device in one measurement session without losing the integrity of measurement data, which makes it possible to measure a part that is larger than the measuring range of the device. The ...
Adding custom components to UCC Server
The attached document explains how to add custom components to UCC Server. Please direct any requests for assistance with specifics to Renishaw.
Renishaw UCC Suite (Server) upgrade sequence
It may be necessary at times to upgrade UCC Suite from a very old version (4.4 for instance) to a more current release (ie: 5.8). Due to some required upgrades that occur during intermediate steps, Renishaw recommends upgrading in the following ...
Creating a Dynamic Data Export (DDE) Report
Dynamic Data Export (DDE) is a powerful tool that allows you to control the export of report data to Microsoft Excel. For each type of report, the DDE dialog displays a grid similar to that report type and allows you to specify which report cells are ...
Adding CAD Furniture
What is Furniture? The furniture feature allows a user to define fixed models in the workspace that the system will consider when planning paths to avoid collisions. These furniture pieces will remain at their defined location and orientation when ...
Renishaw - UCC I++ Program Migration 3.7
Important changes to Get Probe Assembly Operation for version 3.7 on I++ systems Starting from CMM-Manager 3.7, Get Probe Assembly Operation(s) will use the probe name to retrieve the probe. The probe name will be saved to the project/program. ...
Operation Planner Tutorial
Do you manufacture parts in distinct operations? Is the part also inspected after/during each of these distinct manufacturing operations? Are you creating unique CMM-Manager programs for each operation? If so, there is a better way ...Meet Operation ...