Renishaw - UCC T3 Plus (+) / S3 / T5 / I++ (DCC)
DCC
Models: UCClite, UCClite2, UCC1, UCC2, Fusion, T3, T3+, T5, S3, S3+
UCC Suite
Due to a change in how UCC Server deals with "blocks" of commands, CMM-Manager (and some other brands of inspection software) will not run properly with SP25, PH20, or REVO.
*** CMM-Manager with UCC Server 5.6.x, 5.7.0, 5.7.1, 5.9.x , or 5.10.0 version is not supported
***
*** UCC Server 5.7.2 - 5.8.6 are acceptable ***
We will not be able to offer assistance with systems running UCC Server 5.6.x or 5.7.0 / 5.7.1 / 5.9.x / 5.10.0 with SP25, PH20, or REVO.
Starting in version 3.7 (UCC Suite 5.0.3+ must be used), Full Sync (X-Path) is supported in CMM-Manager. Users will no longer configure the machine, probes, etc. in CMM-Manager; all machine and probe data will sync to CMM-Manager upon connection to UCC Server via I++ interface. See the attached UCC I++ Server User Guide for details: User Guide - UCC I++ Server.pdf.
Suggested software versions (CMM-M / UCC Suite)
3.6 / 5.0.5 (All)
3.7 / 5.0.5 (PH20) - 5.1.0 (All others)
3.8 / 5.7.2
3.9 / 5.7.2
3.9 SP2 / 5.7.2
3.10 / 5.7.2
2020 / 5.7.2
2021 / 5.7.2
PH20 Head ReQualify can now be done in UCC Server - use command RWReQualify(Head()) from the command tab in UCC Server.
PH20 will exhibit slower performance when running programs in version 3.6. This was fixed in version 3.6 SP1. If you are running 3.6 and have not yet updated to SP1, please download the
IQIppDmeHotFixfor3.6.zip and replace the IQIppDme.dll, which is located "C:\Program Files (x86)\Nikon\CMM-Manager 3.6\Driver\."
3.9 SP2 adds support for "direct connect" for systems that do not utilize SP25/Scanning or PH20. For more information, see
UCC Direct 2.0 (DCC)
Related Articles
Renishaw - UCC Direct 2.0 (DCC)
UCC Direct 2.0 supports a wide variety of configurations running on a Renishaw UCC controller with tactile probing. UCC Direct 2.0 uses a sub-set of I++ commands via UCCserver and the ClientTool environment. However, all user interaction is in ...
Renishaw - UCC Direct 2.0 (DCC) - Controller / UCC Suite versions
The following table lists the supported controllers and the versions of the UCC Suite required for each. The following UCC Suite versions are not supported: 5.6.x 5.7.0, 5.7.1 5.9.x 5.10.0 Information is current as of Dec 2024 Controller UCC Suite ...
Renishaw - UCC Direct 2.0 (DCC) - Hardware Diagrams
Supported and tested configurations: Manual Probe Head PH10 direct to UCC T3 PLUS (No external PHC10) PH10 to PHC10 - PHC10 controlled via RS232 to the Host PC PH10 to PHC10 - PHC10 controlled via RS232 to controller
Renishaw - Setup the UCCserver Client Tool Environment
You must be running UCC Suite 4.7 or above. UCC T3 (Fusion) and UCC Lite-2 controllers must use UCC suites between 4.7 and 4.8. UCC Suite 4.8 is recommended. UCC2-2 and newer controllers should use UCC suites 5.1 and above. (Due to a Renishaw bug, ...
Hexagon (B&S) - Sharpe2 (DCC)
Sharpe2 Default settings: Com Port Settings: 4800, E, 7, 1 If the downl.oad file fails to load, try this: Open C:\ProgramData\QxSoft\CMM-Manager [current version]\Driver\SharpeDriver.ini Find the line: DOWNLOAD_NEW 0 // 0 - old method, 1 - new method ...