Renishaw - UCC Direct 2.0 (DCC) - Controller / UCC Suite versions
The following table lists the supported controllers and the versions of the UCC Suite required for each.
The following UCC Suite versions are not supported:
5.6.x
5.7.0, 5.7.1
5.9.x
5.10.0
Information is current as of Dec 2024
Controller | UCC Suite Requirements |
UCC1 | N/A (Obsolete) |
UCClite | N/A (Obsolete) |
UCClite-2 | 4.7.0 --> 4.8.4 |
UCC2 ** | 4.7.0 --> 5.5.1 |
UCC2-2 ** | 4.7.0 --> 5.5.1 |
UCC T3/Fusion | 4.7.0 --> 4.8.4 |
UCC T3 PLUS | 4.7.0 --> 5.5.1, 5.7.2 --> 5.8.6, 5.10.1 |
UCC T3-2 | 4.7.2 --> 5.5.1, 5.7.2 --> 5.8.6, 5.10.1 |
UCC S3 * | 4.7.0 --> 5.5.1, 5.7.2 --> 5.8.6, 5.10.1 |
UCC T5 | N/A |
UCC MT5 | N/A |
UCC S5 | N/A |
* When used as a UCCT3. SP25/Scanning is not supported
** Renishaw support for UCC2(-2) ends with 5.5.x in 2020
- UCC1, UCClite, UCC T5, UCC MT5, and UCC S5 are not supported
- All configurations require a minimum of UCC Suite 4.7.0, except as noted below.
- UCClite-2 and UCC T3/Fusion require a UCC Suite version between 4.7.0 and 4.8.4
- UCC T3-2 requires a minimum of UCC Suite version 4.7.2
Related Articles
Renishaw - UCC Direct 2.0 (DCC)
UCC Direct 2.0 supports a wide variety of configurations running on a Renishaw UCC controller with tactile probing. UCC Direct 2.0 uses a sub-set of I++ commands via UCCserver and the ClientTool environment. However, all user interaction is in ...
Renishaw - Setup the UCCserver Client Tool Environment
You must be running UCC Suite 4.7 or above. UCC T3 (Fusion) and UCC Lite-2 controllers must use UCC suites between 4.7 and 4.8. UCC Suite 4.8 is recommended. UCC2-2 and newer controllers should use UCC suites 5.1 and above. (Due to a Renishaw bug, ...
Renishaw - UCC Direct 2.0 (DCC) - Setup/Upgrade CMM-Manager
If you have not done so, please set up the UCCserver client environment first. Instructions may be found here. For I++ users upgrading to UCC DIrect 2.0 Ensure that the existing installed version of CMM-Manager is fully synced with UCCserver. This ...
Renishaw - UCC T3 Plus (+) / S3 / T5 / I++ (DCC)
DCC Models: UCClite, UCClite2, UCC1, UCC2, Fusion, T3, T3+, T5, S3, S3+ UCC Suite From Renishaw here. Due to a change in how UCC Server deals with "blocks" of commands, CMM-Manager (and some other brands of inspection software) will not run properly ...
Renishaw - UCC Direct 2.0 (DCC) - Hardware Diagrams
Supported and tested configurations: Manual Probe Head PH10 direct to UCC T3 PLUS (No external PHC10) PH10 to PHC10 - PHC10 controlled via RS232 to the Host PC PH10 to PHC10 - PHC10 controlled via RS232 to controller