Deva 036 Camera Setup

Deva 036 Camera Setup

  1. Download the latest Deva CMM Vision Probe drivers from Deva website: https://www.deva.co.uk/products/cmm-vision-probe-fully-autochanging-renishaw-autojoint

 

  1. Install/Update Deva USB Camera device driver (1)
  • From Windows Device Manager, right-click on the Deva USB Camera device, and select “Update Driver”
  • Select “Browse my computer for drivers”
  • Browse to the unzipped driver folder, e.g. “C:\deva036usb24\Drivers”, and check “Include subfolders”, and click “Next”

 

  1. Register DirectShow Driver (2)
  • Copy the 64-bit DirectShow driver file “deva028.ax” from the unzipped folder “\deva028036directshow19\amd64\” to “C:\Deva”
  • Run Windows CMD Prompt as Admin
  • Enter this command:  regsvr32 “C:\Deva\deva028.ax"

 

  1. Launch CMM-Manager as Admin
  • Go to menu System > Machine Setup > Video tab
  • Select “Deva Camera” under Video Source, click “Apply”, then “Connect”
  • Select “Video Capture Filter…”, and select “Deva 036” under Camera, then click “Apply” and “OK”
  • Select “Video Capture Pin…”, and select “RGB32” under Colour Space, and “10247x468 @ 18 fps” under Frame Size, then click “Apply” and “OK”.
  • Click “Apply” button on the Machine Setup dialog, and then “OK”.

 

  1. Exit CMM-Manager, and re-launch CMM-Manager to make sure settings are saved, and live video and lighting work properly.
    • Related Articles

    • Deva Installation and Setup (DCC)

      This article will guide you through the complete installation and setup of CMM-Manager on a Deva DCC system. The DEVA DCC CMM-Manager Installation Guide and a sample Deva System Config file are attached below. New Installations: Important Notice Some ...
    • Deva Installation and Setup (Manual)

      This article will guide you through the complete installation and setup of CMM-Manager on a Deva Manual system. The DEVA Manual CMM-Manager Installation Guide and a sample Deva System Config file are attached below. New Installations: Important ...
    • Common Setup Procedures

      This article describes the common machine setup procedures for most configurations. Select Machine Setup Select "System | Machine Setup" from the CMM-Manager ribbon bar. (Note: The machine setup password is "service".) Setup Machine Properties Switch ...
    • General Setup Procedures

      This article contains general CMM-Manager setup procedures that apply to most configurations. Setup the Probe Assembly Select "Probe | Probe Assembly" from the CMM-Manager ribbon bar. Define the probe assembly to match the actual probe mounted on the ...
    • Renishaw - Setup the UCCserver Client Tool Environment

      You must be running UCC Suite 4.7 or above. UCC T3 (Fusion) and UCC Lite-2 controllers must use UCC suites between 4.7 and 4.8. UCC Suite 4.8 is recommended. UCC2-2 and newer controllers should use UCC suites 5.1 and above. (Due to a Renishaw bug, ...