Related Articles
VB Script - End program or display error if Dim is Out of Tolerance
You can retrieve report data into VB using the “GetReportInfo()” function. double GetReportInfo( CString sReportName, CString sReportType, int nIndex ) Return Value The value at the specified cell of the report if the function is successful. The ...
Hexagon (B&S) - Sharpe2 (DCC)
Sharpe2 Default settings: Com Port Settings: 4800, E, 7, 1 If the downl.oad file fails to load, try this: Open C:\ProgramData\QxSoft\CMM-Manager [current version]\Driver\SharpeDriver.ini Find the line: DOWNLOAD_NEW 0 // 0 - old method, 1 - new method ...
Hexagon (B&S) - Sharpe32 (DCC)
Sharpe32 Default settings: Com Port Settings:4800, E, 7, 1 Configuration File: Downl.oad or Syspar.asc file is required. See the install guide for details on the location and usage of these files. Error Map: Comp.dat or Comp.asc file will likely be ...
zCat Portable CMM (DCC)
zCat Portable CMM Minimum Firmware: BOOT-02-06-18 (original release 3.7) Recommended Firmware: BOOT-06-01-18 (tested since 3.8 SP1) License Type: I++ / DME Required Software: Cat Smarts (included with hardware) I++ Server Type set as zCatServer - ...
Optical CMM / Krypton - K-CMM / Krypton (direct)
Krypton OCMM K-CMM software needs to be installed